Power Source |
Usable power supply unit: VX-200PS 24V DC (operational range: 20V – 40V DC) Two power inputs construction enables dual- redundant power supply. |
Current Consumption |
Under 1.1A (maximum value in the power operating range) Under 0.8A (when operated on 24V DC) |
Indication/Operation |
SX link access indicator: 2 LAN access indicator: 1 Mode indicator: 3 (EMERGENCY/STANDBY/CPU OFF) Failure indicator: 3 (GENERAL/CPU/SX LINK) Power indicator: 1 (POWER) Run indicator: 1 (RUN) Failure control switch: 3 (AUX/RESET/LAMP TEST) |
SX Link |
|
Network I/F |
2 100BASE-TX circuits, RJ45 connector |
Matrix System Specification |
Bus: 16 Audio input: Max. 64 ch Audio output: Max. 128 zones Contact input: Max. 136 Contact output: Max. 136 Priority control: 256 steps Event log: Max. 10,000 events |
Matrix System Configuration |
Connectable SX-2100AI No: Max. 8 units Connectable SX-2000AO No.: Max. 16 units Connectable RM-200S No.: Max. 32 units (up to 4 RM-200S per SX2100AI) |
Connection Cable/Device |
Shielded Category 5 twisted pair cable for LAN (CAT5-STP)(Connect SX-2100AI and SX-2000AO via the switching hub specified by TOA) Note: This network must be made physically independent from other LAN. |
Switching Hub |
7 stages |
Maximum Cable Distance |
100m (between this unit and a switching hub) |
LAN |
|
Network I/F |
1 10 BASE-T/100 BASE-TX circuit (selectable by automatic recognition), RJ45 connector for maintenance use |
Network Protocol |
TCP/IP |
Connection Cable |
Shielded Category 5 twisted pair cable for LAN (CAT5-STP) |
Maximum Cable Distance |
100m (between this unit and a switching hub or PC) |
Analog Link |
Input/Output Connector Output: 2, RJ45 connector Connection Cable Shielded Category 5 twisted pair cable for LAN(CAT5-STP) (1 pair of audio wire + 1 pair of CPU OFF + 1 pair of control wire (system reset/standby) + 1 pair of connection check wire) |
Maximum Cable Distance |
Total length of analog audio link: 800m |
Failure Data Input |
3 inputs (ACK/RESET/LAMP TEST), no-voltage make contact input,open voltage: 24V DC, short-circuit current: 2mA, photo coupler input,removable terminal block (12 pins) |
Failure Data Output |
4 outputs (CPU FAULT/GENERAL FAULT/CPU OFF/BUZZER), C contact, no-voltage make contact output, relay contact output (withstand voltage: 40V DC, control current: 2 – 300mA), RJ45 connector |
Control Input |
8 inputs, no-voltage make contact input, open voltage: 24V DC, short-circuit current: 2mA, photo coupler input, removable terminal block (12 pins) |
Control Output |
8 outputs, C contact, no-voltage make contact output, relay contact output (withstand voltage: 40V DC, control current: 2 – 300mA), removable terminal block (12 pins) |
Memory Card |
Insertion slot: 1 (use of supplied CF card (128MB)), set data and log data stored |
Operating Temperature |
0°C to +40°C |
Operating Humidity |
35% to 80% RH (no condensation) |
Finish |
Panel: Aluminum, black, alumite, Case: Surface-treated steel plate |
Dimensions |
482 (W) × 44 (H) × 333 (D)mm |
Weight |
3.8kg |
Accessory |
CD (PC setting software) × 1, CF card (128MB) × 1, Removable terminal plug (4 pins) × 1, Removable terminal plug (12 pins) × 4, Rack mounting screw × 4, (–) Screw driver × 1 |